Applies to:
SiteScope 11.24
Windows 2012 (64bit)
Issue:
Installed HP_Operations_Agent_11.14_for_Windows_64bit because the OA included with SiteScope 11.24 isn’t compatible with Windows 2012.
The agent appears to have installed fine.
However, when running the SiteScope configuration Wizard it hangs, and doesn’t recover.
Receiving error message about the opr-policy-activation.
Steps:
To fix this, perform the following steps.
1. Navigate to: C:\SiteScope\installation\components\oa_policy_signing_tool and select the platform.
2. Execute the MSI and please test again.